Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Journal of Biomedical Engineering ; (6): 184-187, 2016.
Article in Chinese | WPRIM | ID: wpr-357830

ABSTRACT

Terahertz waves have unique properties and advantages, which makes it gain increasing attention and applications in the biomedical field. Burns is a common clinical trauma. Since the water-sensitive and non-destructive characteristics of terahertz, terahertz imaging techniques can be used to detect burns. So far, terahertz imaging technology in the assessment of burn injuries has been developed from ex vivo to in vivo, and high-resolution images can be obtained through the gauzes and plasters. In this paper, we mainly introduces the application of terahertz imaging technology and development in the assessment of burn injuries.


Subject(s)
Humans , Bandages , Burns , Diagnosis , Terahertz Imaging
2.
International Journal of Laboratory Medicine ; (12): 1062-1064, 2016.
Article in Chinese | WPRIM | ID: wpr-486628

ABSTRACT

Objective To assess the relationship between the serum IgG antibody titer of pregnant women and the hemolytic dis‐ease of newborn(HDN) .Methods Using microcolumn gel coombs card assay method to determine titer of 255 cases of couples an‐tenatal serum IgG antibody and ABO blood group .Results with 195 cases of ABO‐incompatible couples ,the positive rate of abnor‐mal serum IgG antibody(≥64)was 93 .8% .The titer of anti‐A/B IgG :in 12(6 .2% ) cases was <64;in 12(6 .2% )cases was 64;in 60(30 .8% )cases was 128 ;in 39(20% )cases was 256 ;in 45(23 .0% )cases was 512 ;in 27(13 .8% ) cases was 1 024 .There were no statistical differences between IgG anti‐A(B) titers distribution between A/O blood group matching and B/O blood group matching (χ2 =4 .361 ,P=0 .499) ,IgG anti‐A( B) titers was higher in AB/O blood group matching .Conclusion we can take early and effec‐tive prevention ,treatment ,reducing the incidence of HDN by the determination of prenatal serum IgG antibody titers in ABO‐in‐compatible couples ,which is important for the population of eugenics .

3.
Journal of Biomedical Engineering ; (6): 983-988, 2015.
Article in Chinese | WPRIM | ID: wpr-359534

ABSTRACT

Vascular perfusion distribution in fibroids contrast-enhanced ultrasound images provides useful pathological and physiological information, because the extraction of the vascular perfusion area can be helpful to quantitative evaluation of uterine fibroids blood supply. The pixel gray scale in vascular perfusion area of fibroids contrast-enhanced ultrasound image sequences is different from that in other regions, and, based on this, we proposed a method of extracting vascular perfusion area of fibroids. Firstly, we denoised the image sequence, and then we used Brox optical flow method to estimate motion of two adjacent frames, based on the results of the displacement field for motion correction. Finally, we extracted vascular perfusion region from the surrounding background based on the differences in gray scale for the magnitude of the rich blood supply area and lack of blood supply area in ultrasound images sequence. The experimental results showed that the algorithm could accurately extract the vascular perfusion area, reach the precision of identification of clinical perfusion area, and only small amount of calculation was needed and the process was fairly simple.


Subject(s)
Female , Humans , Algorithms , Contrast Media , Leiomyoma , Diagnostic Imaging , Motion , Perfusion , Ultrasonography
4.
Journal of Medical Research ; (12)2006.
Article in Chinese | WPRIM | ID: wpr-563683

ABSTRACT

Objective The anti-HCV positive results obtained from ELISA assay was confirmed by using protein microarray, and then the difference of detection rate of different antibody function domains was studied through observing low risk population. Methods The HCV mixing antigen, core area antigen, NS3 domain antigen, NS4 domain antigen, NS5 domain antigen were spotted on the slide. The 48 serum samples, which was positive HCV detected by using ELISA assay, were chosen from the specimens applying to investigation of viral hepatitis seroepidemiology in 2001, and furthermore the antibodies containing different function domain were detected by using protein microarray. Results The negative results were obtained from different domains of 15 samples. Then 1-4 antibodies from 33 samples were positive. The total detection rate of anti-C, anti-NS3, anti-NS4, anti-NS5 was 51.5%, 51.5%, 48.5% and 57.6% respectively. In these above statistics, the detection rate of anti-C from Zhoushan, Quzhou, Wenzhou, Shaoxing was 53.3%, 33.3%, 44.4%, 66.7% respectively; the detection rate of anti-NS3 was 33.3%, 100%, 55.6%, 66.7% respetively; the detection rate of anti-NS4 was 60.0%, 0%, 33.3%, 66.7% respectively; 抗the detection rate of anti-NS5 was 66.7%, 0%, 44.4%, 83.3% respectively. Conclusion The difference of distribution of different antibody function domains existed through studying low risk population. Moreover, the protein microarray assay was highly specific for detecting and identifying HCV antibody in low risk population.

5.
Space Medicine & Medical Engineering ; (6)2006.
Article in Chinese | WPRIM | ID: wpr-580814

ABSTRACT

Objective To make the validation of intravascular ultrasound elastography (IVUSE) for detecting the plaque.Methods A plain strain model of vascular plaque was established and then the RF signals of IVUS were produced.The radial displacement distribution and strain distribution were calculated through 1D numerical optimization based on the RF signals.Then the elastic moduli distribution was reconstructed by finite element method (FEM) and iteration method.Results The three elastic parameters,displacement/strain/moduli,all could detect the plaque.Elastic moduli presented the information of the shape and size of the plaque,meanwhile,the displacement and strain distributions could not give the information clearly.Conclusion Elastic modulus is proved to be superior to the other two parameters in detecting the plaque,whereas it is subject to the accuracy of the strain's estimation.

6.
Journal of Third Military Medical University ; (24)2003.
Article in Chinese | WPRIM | ID: wpr-556927

ABSTRACT

Objective To develop a real-time QRS complex detection algorithm of dynamic ECG signals for the GPRS mobile telemonitoring system. Methods Before the first and second derivatives of ambulatory ECG signals were processed by moving average method, the signals sampled from CM5 monitoring lead were filtered with the average of continuous four ECG sample signal points. The R waves could be detected precisely by local minima of second derivatives and Q & S waves were located correctly by cross-zero points of first derivatives of ambulatory ECG signals in a short-time searching windows. The QRS recognition thresholds, which could revise themselves according to the detected values and vary with the analyzing signals, were designed in this paper. Results With a polynomial computation complexity, the novel algorithm insensitive to baseline draft and noise caused by mobile communication filtered power-line interference and most of muscle noise and reduced the search time below 0.02 s during detecting each Q wave, R wave and S wave. For the normal and clinical patients, this algorithm correctly detected up to 99.8% of the QRS complex of ambulatory ECG signals. Conclusion The algorithm can meet the need of real-time QRS complex detection and analysis for the GRRS mobile ECG telemonitoring system.

7.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-583661

ABSTRACT

Healthcare at home is accepted little by little with the development of medical service in the community. This paper introduces the design method of mobile ECG monitoring system terminal for healthcare at home. The adoption of active electrode and digital trap contributes to the elimination of the external interference. Low-power-consumption MSP430 micro-controller applied, the realtime acquisition, procession and transmission to PDA of ECG are performed.

SELECTION OF CITATIONS